Attune — the science
This is the reasoning behind every number in the recommendation engine (src/engine). The rule from the spec: every threshold and constant cites a reputable source, nothing is invented, and anything without a good source says so and is marked tunable.
How to read the status column used throughout
| Status | Meaning |
|---|---|
| Primary | Read from the source document itself. |
| Abstract | Confirmed from the paper's abstract or a bibliographic record. The full text was not available, so details beyond the abstract are not claimed. |
| Secondary | A well-known value taken from sources that cite the original, which was not read. |
| Reference code | Taken from a published reference implementation and checked numerically against it. |
| Derived | Follows by arithmetic from sourced values. |
| Tunable | No good source. The value is a judgment, the reasoning is stated, and it is a named constant so it can be changed. |
Every tunable value is collected in §13.
1. The claim
A runner is comfortable when the heat they make equals the heat they lose at a skin temperature and sweat rate they find acceptable:
M − W = (C + R) + E_sk + (C_res + E_res) + S
M is metabolic heat, W external work, C + R dry loss through clothing by convection and radiation, E_sk evaporation from skin, the respiratory terms are heat lost in breath, and S is heat stored in the body (which is what raises core temperature).
A temperature table with a fixed "+15–20°F" offset cannot represent this, because wind, sun, humidity, rain and effort each change a different term. Attune models the terms.
2. Heat production
Running speed → oxygen cost. ACSM running equation for level ground, with speed S in m/min:
VO₂ (ml·kg⁻¹·min⁻¹) = 0.2·S + 3.5
Source: ACSM's Guidelines for Exercise Testing and Prescription metabolic equations. Status: Abstract (confirmed through secondary reproductions). The equation is intended for speeds above about 5 mph, which covers all three efforts. It is known to overpredict in some trained populations by 10–15%; the personal offset absorbs that.
Oxygen → heat. 20.9 J per ml O₂ (the standard energy equivalent at a mixed respiratory quotient). On level ground running does no net external work, so W = 0 and all of it becomes heat. Status: Derived.
Reference body. 70 kg and 1.8258 m² (the DuBois surface area of the two-node model's standard person). Status: Reference code. Heat per m² of skin rises with body mass, which is one of the things the personal offset absorbs so that the app never has to ask for weight or height.
Pace is the one thing the runner says about themselves. A slider from 13:00 to 5:00 a mile, remembered on the device. It changes two things the weather cannot tell us: how much heat they make, and how much wind they make by moving.
| Pace | Speed | Heat production |
|---|---|---|
| 12:00 | 5.0 mph | 405 W/m² |
| 10:00 (default) | 6.0 mph | 477 W/m² |
| 8:00 | 7.5 mph | 584 W/m² |
| 6:30 | 9.2 mph | 708 W/m² |
| 5:30 | 10.9 mph | 828 W/m² |
The default, 10:00. Strava's 2018 Year in Sport reported an average pace of 9:48 per mile across all uploaded runs (9:15 men, 10:40 women). RunRepeat's State of Running 2019 (107.9 million recreational results) puts the average marathon at 4:32:49, about 10:25 per mile. 10:00 sits between them. Status: Tunable.
Why faster means lighter, not warmer clothes. Running faster does two things at once. It makes more wind over the body, which cools. And it makes more heat, which is the larger effect: heat rises in step with speed, so 6:30 a mile produces about 75% more than 12:00. Convective cooling grows more slowly than airspeed (roughly as its 0.6 power), so even in still air the wind a 6:30 runner makes carries off about 45% more than a 12:00 runner's, and into a 12 mph headwind only about 18% more, because the weather was already supplying most of the airflow. Heat wins, and the faster runner is dressed lighter. Cycling is the opposite case and the source of the opposite intuition: a bike turns the same power into three or four times the speed, and coasts downhill on none, so there the wind wins.
The feels-like number moves much less with pace than the outfit does, because it is measured against a still day at the same pace (§10): it reports the weather, not the effort.
There are no Easy, Workout and Race buttons. There used to be. They set a pace, which the slider does exactly, and they switched between dressing for comfort and dressing for least strain. Compared at the same pace, that switch was worth about one tier on the hands; pace had done the rest. One rule (§8.3) now serves every pace.
Why pace and not effort. Two people at 8:30 a mile, one jogging and one racing, make about the same heat for their size: heat follows speed and body mass, not how hard it feels. Fourteen men, seven fit and seven unfit, matched for mass, cycled at the same heat production: core temperature rose 0.87°C in both and sweat loss was 434 against 440 ml, though one group was at 40% of maximum and the other at 58%. Matched instead for relative effort, the fitter group made more heat, because they were doing more work, and ran hotter (Jay et al. 2011). So a race setting would not change the heat balance; the pace already has. What does differ between runners at the same pace, running economy (about ±10%) and body size, is what the personal offset absorbs. Status: Abstract.
The warm-up and cool-down. The model is run a second time 30% slower (a group that works out at 6:15 jogs at about 8:00), and whatever that needs on top is listed as "For the warm-up and cool-down, or any slower stretch". Status of the 30%: Tunable.
3. The body
Attune uses Gagge's two-node model: a core and a skin shell, with blood flow carrying heat between them and sweating, vasodilation, vasoconstriction and shivering driven by the two temperatures. It is the model behind ASHRAE's Standard Effective Temperature (ASHRAE Handbook — Fundamentals, ch. 9; Gagge, Fobelets & Berglund 1986).
src/engine/twonode.tsis a port of pythermalcomfort 4.6.1's implementation. Status: Reference code.twonode.test.tschecks core temperature, skin temperature, wettedness, sweat loss and thermal sensation against the Python reference for five cases from rest to 9 met, hot to −5°C.- One structural change: the original takes an air speed and uses indoor heat-transfer correlations. The port takes heat-transfer resistances instead, so the outdoor terms in §4 can be supplied from ISO 11079. The test runs the port with the original correlations to prove the body is unchanged.
- The model runs minute by minute in 30-second steps, so warm-up, the turnaround and changing weather on a long run are simulated rather than assumed.
Why this model. It predicts skin temperature and sweat rather than assuming them, it costs under 2 ms per recommendation in a browser, and it has a public reference to verify against. Its limits: one skin compartment (it cannot tell arms from legs — see §8.4), fixed set points, and validation mostly at lower metabolic rates than running. JOS-3 or the UTCI-Fiala model would resolve body segments but are far too heavy for a page that must answer on load.
4. The environment
4.1 Wind at body height
Forecast wind is reported at 10 m. Wind at body height is taken as two thirds of it. Source: the NWS wind chill index, which makes the same adjustment from 33 ft to face level (NWS Wind Chill brochure; Osczevski & Bluestein 2005). Status: Primary (the brochure states the height correction; the 2/3 factor is from the index's published derivation). UTCI's operational procedure gives nearly the same number from a log profile (0.68).
This is an open-terrain figure. A tree-lined or built-up route is more sheltered, so Attune runs slightly conservative on wind.
4.2 Airflow over the runner
The air a runner feels is wind plus their own speed. The run is modeled as an out-and-back: headwind out, tailwind home, per the spec.
- Headwind leg: v = v_run + ⅔·v₁₀
- Tailwind leg: v = |v_run − ⅔·v₁₀|
The headwind leg is where a runner gets cold. The tailwind leg is where they overheat, because the wind cancels the airflow their own motion makes. An outfit has to survive both.
4.3 Heat transfer in wind (ISO 11079)
ISO 11079 (Determination and interpretation of cold stress when using required clothing insulation), Annex A, with insulation in m²K/W, relative air speed v and gait speed w in m/s:
Boundary air layer: I_a,r = 0.092·e^(−0.15·v − 0.22·w) − 0.0045
Total insulation as worn: I_T,r = I_T · [0.54·e^(−0.15·v − 0.22·w)·p^0.075 − 0.06·ln(p) + 0.5]
p is the air permeability of the outer fabric in l/(m²·s): 1 impermeable, 50 dense weave, 1000 open knit. The second equation is Havenith & Nilsson's (2004, with the published erratum) correction for wind and body movement. Status: Reference code (coefficients match pythermalcomfort's ireq model; the ISO 9920 equivalents were confirmed in a 2020 comparison of ISO 7933 and ISO 9920, J Physiol Anthropol, doi:10.1186/s40101-020-00235-9).
This one equation is why a thin wind jacket matters: at a 7 m/s relative wind an open knit keeps about a third of its still-air insulation and a windproof layer keeps about two thirds.
Used outside its validated range in two ways, both flagged:
- Gait speed is validated to 1.2 m/s (a walk). Running is faster, so the limb-pumping term is held at 1.2 m/s.
- The correction was fitted on ensembles of 1.49–3.46 clo total insulation. Running kit is lighter.
Static air layer 0.085 m²K/W and clothing area factor f_cl = 1 + 0.31·I_cl(clo) are from ISO 11079 / ISO 9920. Status: Reference code.
4.4 Sun
Sun is taken from forecast solar radiation, split into direct beam and diffuse, not from cloud cover. Absorbed solar load per m² of body follows ASHRAE 55's SolarCal method (Arens et al. 2015):
E_solar = f_eff · [ f_p·I_direct-normal + ½·I_diffuse + ½·I_global·ρ_ground ] · (α_sw / α_lw)
| Term | Value | Source | Status |
|---|---|---|---|
| f_eff, fraction of body exchanging radiation | 0.725 | SolarCal | Reference code |
| f_p, projected area factor | 0.303 → 0.082 by sun altitude | SolarCal table, averaged over all bearings because an out-and-back faces every way | Reference code + Derived |
| α_sw, shortwave absorptivity | 0.7 | ASHRAE 55 default | Reference code |
| α_lw, longwave emissivity | 0.95 | ASHRAE 55 | Reference code |
| ρ_ground, ground albedo | 0.2 | Typical for grass and pavement | Tunable |
| ρ_ground with snow cover | 0.8 | Typical for snow | Tunable |
The load is converted to a rise in mean radiant temperature with SolarCal's h_r = 6 W/m²K. When the sun is below the horizon the solar term is exactly zero regardless of what the radiation fields say, which is how "night and twilight mean no sun" is guaranteed. Sun altitude is computed from time and location with the Astronomical Almanac's low-precision formula.
Simplification: open sky, no shade. A shaded route is cooler than Attune thinks on a sunny day.
4.5 Moisture
Humidity. The body model works in vapour pressure, and the vapour pressure of the air is the saturation pressure at the dew point. So dew point enters directly and relative humidity is never used to decide anything. On the warm side this is the term that limits sweat evaporation.
Rain and wet snow act three ways. This is the least well-sourced part of the engine.
| Effect | Value | Source | Status |
|---|---|---|---|
| Wet fabric conducts better | Insulation −15% when soaked | Holmér 1985, wear trials: wet clothing insulated 15% less than dry at rest | Abstract |
| Rain water is warmed by the body | 1.16 W/m²K per mm/h landing | Specific heat of water | Derived |
| Soaked kit keeps skin wet, so it evaporates whether or not the runner is sweating | Skin wettedness held at ≥ 0.3 when soaked | None for runners. Set so the cold-rain anchor lands, then checked that warm rain stays mild | Tunable |
| How fast kit soaks | Fully wet at 1 mm/h | Judgment | Tunable |
| What counts as wet at all | 0.2 mm/h. Below it the hour is treated as dry | Judgment; roughly the lightest rate reported as drizzle | Tunable |
| A shell keeps rain off | Wind jacket or wind pants 60%, rain shell 90%, vest 20%, of the half of the body it covers | Judgment | Tunable |
| Dry snow brushes off | Below −2°C, snow wets 20% as much as rain | Judgment | Tunable |
Supporting evidence that the direction and rough size are right: Bröde et al. (2008) measured a 16% drop in total insulation with a wet layer while walking, and found the evaporative effect larger than the conductive one. Thompson & Hayward (1996) and Weller et al. (1997) showed cold rain with wind drives body temperature down during exercise that is comfortable when dry.
The result in the model: steady rain at 38°F with a 10 mph wind feels like 17°F to a runner. That is deliberately heavy, as the spec asks.
Timing. Open-Meteo reports precipitation as a total for each hour. Each value is applied to the whole of its hour, not blended toward the next, so rain forecast for the following hour does not leak into a run that finishes before it starts.
4.6 Conditions typed in by hand
The page can be given the weather directly instead of a forecast, to see what it would say about some other day. Six inputs, held steady for the whole outing, are turned into the same hourly weather the forecast supplies (src/app/conditions.ts), and the engine runs unchanged.
| Input | Becomes | Status |
|---|---|---|
| Air, wind | Used as given; gusts taken as 1.5× the wind | Gust factor Tunable (gusts only feed the wording) |
| Humidity | The dew point that gives that humidity at that air temperature, by the engine's own vapour pressure curve | Derived |
| UV index | Used as given; 0 when the sky is dark | — |
| Sky: full sun | Sun 45° up, 800 W/m² beam, 100 W/m² diffuse | Tunable: a clear midday in spring or autumn at mid-latitudes |
| Sky: some sun | Sun 45° up, 350 W/m² beam, 220 W/m² diffuse | Tunable |
| Sky: overcast | Sun 45° up, no beam, 100 W/m² diffuse | Tunable |
| Sky: dark | Sun 20° below the horizon, no light | — |
| Falling: light rain, steady rain, snow | 0.5 mm/h; 2.5 mm/h; 1 mm/h as snow, with snow on the ground | Tunable, chosen to sit either side of the 1 mm/h "fully wet" rate in §4.5 |
A typed day has no place, so there are no alerts and no air quality, and it is never asked about afterward for the personal offset.
4.7 Where the weather comes from, and tying "now" to a thermometer
| What | Source | Why this one |
|---|---|---|
| Air temperature, dew point, wind, gusts, sunlight, rain and snow, by the hour | Open-Meteo, which over the US serves NOAA's HRRR model (3 km grid, re-run every hour) blended into GFS further out | The finest-grained public forecast, with every variable the heat balance needs from one consistent model, including the beam and diffuse sunlight no other free source gives |
| The air temperature and dew point right now | The latest reading from the nearest National Weather Service station, preferring airports | A measurement beats a forecast for the present, and it is the number people check against |
| UV index | Open-Meteo; spot-checked against the EPA/NWS forecast in §11.1 | Hourly, cloud-aware |
| Air quality | AirNow monitors where one is near, Open-Meteo's model otherwise | Measured beats modelled |
| Alerts | National Weather Service | The issuing authority |
Why a correction is needed. A forecast model is typically a degree or three off at any given place and hour. On 12 October 2026 at 7:36 am, compared against airport readings at the same time, the HRRR-based forecast was 1.2°F low at Oconomowoc, about right at Denver, 1.5°F low at Miami, 1.5–3.5°F low at Seattle and up to 4.6°F low at Phoenix. NOAA's statistically corrected blend (NBM, also offered by Open-Meteo) was no better on the same morning: closer at three of the five, 4–6°F too warm at Seattle. No model wins everywhere, so the model is kept and corrected against a measurement.
How. The forecast is shifted so it passes through the station's reading at the time the reading was taken. The shift applies in full up to that time and fades linearly to nothing over the next six hours, so the present is measured and tomorrow is the model's. Air temperature and dew point are corrected. On the same morning this put "now" within 1°F of the nearest airport in all five cities and a mountain town. Status: standard practice in nowcasting; the six hours is Tunable.
A reading is only used when it is about the same air:
| Guard | Value | Status |
|---|---|---|
| Station no farther than | 40 km | Tunable |
| Station within this height of the forecast point | 150 m (about 1.5°F of lapse rate) | Tunable |
| Reading no older than | 90 minutes | Tunable |
| Gap between reading and forecast no larger than | 6°C: wider is a different air mass or a bad sensor | Tunable |
| Airport stations before others | Maintained to aviation standards, and what other forecasts are checked against | Judgment |
When no reading passes, the forecast stands as the model gave it and the page says nothing about a thermometer.
Wind is not corrected. Airport anemometers report calm below about 3 mph, and wind varies more over a few miles than temperature does, so a station 20 km away is a worse guide to the runner's wind than the 3 km model. Status: judgment.
What the page shows. The number on each hour of the bar, and at the start of the why line, is the air temperature, the same thing every weather app shows, so the two can be checked against each other. How that hour feels to a runner is the bar's colour and the second half of the why line.
5. Clothing
Insulation comes from ASHRAE 55's garment table (via pythermalcomfort's clo_individual_garments), summed per ASHRAE 55. Running kit is not in any standard table, so each garment is mapped to the nearest everyday one. Status of the table values: Reference code. Status of every mapping: Tunable in the sense that it is an analogy, though no number was made up except the singlet's.
| Running garment | Mapped to (ASHRAE 55) | clo |
|---|---|---|
| Singlet | No entry. Assumed slightly under a T-shirt | 0.06 (Tunable) |
| Tee | T-shirt | 0.08 |
| Long sleeve | Long underwear top | 0.20 |
| Midlayer / thermal half-zip | Long-sleeve sweat shirt | 0.34 |
| Vest | Sleeveless vest (thin) | 0.10 |
| Wind jacket or rain shell | Long sleeve shirt (thin) | 0.25 |
| Insulated jacket | Single-breasted coat (thin) | 0.36 |
| Shorts with liner | Short shorts + men's underwear | 0.10 |
| Tights | Long underwear bottoms | 0.15 |
| Thermal tights | Sweatpants | 0.28 |
| Wind pants over tights | + Thin trousers | +0.15 |
| Socks and shoes | Ankle socks + shoes | 0.04 |
Fabric behaviour.
| Property | Knit | Vest over knit | Wind jacket | Rain shell | Status |
|---|---|---|---|---|---|
| Air permeability p, l/(m²·s) | 1000 | 100 | 10 | 1 | ISO 11079 defines the scale and its three anchor classes (1, 50, 1000). Placing each garment on it is Tunable |
| Vapour permeation efficiency i_cl | 0.45 | 0.42 | 0.34 | 0.20 | 0.45 is the two-node model's value for permeable clothing (Reference code). Shell values are Tunable, guided by ISO 9920 / Havenith et al. 1999, where coated and membrane fabrics run about half the permeability of open ones |
An outfit's fabric properties are the area-weighted blend of its top (55%) and bottom (45%), with air permeability blended on a log scale because it spans three orders of magnitude. The 55/45 split is Tunable.
5.1 The detail on each piece
Some pieces carry one line of detail. Each is there because it changes how well the piece works, not to describe a product. Picking a piece, or the matching part of the drawn runner, shows the reason in a sentence or two; those sentences are the "Why" column below, shortened.
| Piece | Detail shown | Why | Status |
|---|---|---|---|
| Base layer (cold) | Close-fitting polyester | Wet clothing insulates less, far less once running (Holmér 1985), and of the common fibres polyester takes up the least water (about 0.4% of its weight at standard conditions, against about 8% for cotton and more for wool), so it loses the least. Wool is not named for or against: no controlled comparison on runners in the cold was found. In the heat and out of the sun the difference has not shown up in body temperature, sweat rate or pace (see the warm-weather row below) | Abstract |
| Midlayer | A half zip lets heat out | Venting is a way to shed heat on the tailwind leg without stopping. Reasoning from the model's own out-and-back, not a study | Tunable |
| Vest | Wind-blocking front | The wind correction in §4.3: a windproof layer keeps about twice the insulation of an open knit in a headwind | Derived |
| Wind jacket | Windproof, with vents | Same, plus Holmér (2008): lower vapour resistance lets a runner go longer before strain | Abstract |
| Rain shell | Vented, not a sealed raincoat | Holmér (2008) | Abstract |
| Gloves | A fold-back mitten flap lets you vent as you warm up | Hands start a cold run vasoconstricted and warm as exercise raises blood flow to them, so the same hands need more cover in the first mile than the fifth. A convertible mitt covers both without carrying two pairs. Mittens are warmer than gloves because fingers share warmth and expose less surface | Reasoning from ACSM cold guidance (Castellani et al. 2021); the specific product advice is Tunable |
| Mittens | Over thin liner gloves | In an Antarctic field study, mittens with liners kept fingers at or above 15°C where unheated gloves did not | Abstract |
| Two sock layers | Thin liner under a thick sock, toes free to move | A thin liner under a thick, dense sock cut blisters from 69% to 40% in 357 Marine recruits; a liner under a thin sock did not (Knapik et al. 1996). Tight footwear restricts blood flow and raises frostbite risk (clinical guidance) | Abstract |
| Thermal tights | Brushed inside | Says what "thermal" means | — |
| Neck gaiter | Over your nose into the wind | Face skin is what the wind chill index measures (§7.1) | Primary |
| Neck gaiter or balaclava, air at 5°F or below | Over your mouth and nose | Air that cold narrows the airways; breathing through fabric warms and wets it first (§7.4) | Abstract, for masks; applying it to a gaiter is a judgment |
| Insulated jacket | Light fill, windproof | Insulation is still air; the wind correction in §4.3 is how much of it a headwind strips from an open fabric | Derived |
| Wind pants | — | Same wind correction, applied to the legs | Derived |
| Long sleeve | — | "Push the sleeves up once the wind is behind you": the same venting reasoning as the half zip | Tunable |
| Singlet, tee | Thin, pale polyester | In direct sun, fabric and colour both matter. Six subjects cycled for an hour with an artificial sun of 724 W/m² on their backs, in white or black polyester and white or black cotton. Heart rate settled at 142 (white polyester), 154 (black polyester), 151 (white cotton) and 160 (black cotton) beats a minute; sweat lost was 649, 666, 704 and 808 g. White polyester was significantly easier than black cotton on both (Nielsen 1990). The suits covered the body, so the effect of a singlet will be smaller; the direction is not in doubt. Out of the sun, it has not been shown to matter. A 2022 review of wearer trials (15–120 minutes, 18–40°C) found few significant differences between natural and synthetic fabrics in temperature, perception or performance, and noted that none had tested the hottest, longest conditions (Di Domenico et al. 2022). Cotton does hold more sweat: the fibre takes up about 8% of its weight in water at standard conditions against about 0.4% for polyester, so a soaked cotton shirt is heavier and slower to dry. That weight has not been shown to cost pace in trials of up to two hours; over many hours it is carried the whole way. Bare arms and shoulders are more skin for sweat to evaporate from (§3) | Abstract; fibre moisture regain is Reference |
| Singlet, with no sun to cover for | Or tarps off | Shown under the singlet whenever the UV index stays under 3 for the whole run (§11.1). Picking it gives the reason, which ends on the page's one joke, "no cooler in the lab, but nobody runs in a lab". It is what the studies found: direct calorimetry measured the same heat storage in a fitted shirt as semi-nude (214 against 211 kJ, D'Souza et al. 2018), and a review concluded that a modest amount of clothing does not change thermoregulation or comfort in warm conditions (Gavin 2003). More cover does cost something: a long-sleeved shirt raised strain over semi-nude at moderate effort under radiant heat (Tsuji et al. 2014) | Abstract |
| Tights | — | Muscle temperature and performance (§9) | Abstract |
| Shorts | — | The bare-leg rule (§8.4): legs are simulated bare and stay comfortable | Derived |
| Cap | — | Cover before sunscreen (§11.1) | Abstract |
| Ear band | Push it up once you warm up | A cold head is least comfortable in the first few minutes of exercise: in 43°F air, after about five minutes a bare head was as comfortable as a warmed one (Mündel et al. 2016). Venting it then is the same reasoning as the half zip | Abstract |
| Hat, balaclava | — | Runner's wind chill on the way out (§7.1, §7.3); the frostbite thresholds for the balaclava | Primary |
| Thin gloves | — | The same warm-up reasoning as the gloves | Tunable |
| Thick socks | — | The body defends its core in the cold by cutting blood flow to hands and feet first (Castellani et al. 2021) | Abstract |
The mitten figure is reported in the study as 15°C; the app shows it as 59°F.
What is deliberately not claimed: that wool stays warm when wet. It is repeated everywhere and may be true, but no controlled comparison was found, so sock fabric is not named.
6. The heat side
6.1 WBGT
Wet bulb globe temperature is computed with Liljegren et al. (2008), the physically based model that solves the natural wet bulb and black globe heat balances separately with no site-specific fitted constants (src/engine/wbgt.ts). It is the method OSHA's outdoor WBGT calculator uses, and a 2023 review of WBGT methods describes it as the most accurate of the published ones because of its physical basis and validation against observations (Brimicombe et al. 2023).
WBGT = 0.7·T_nwb + 0.2·T_g + 0.1·T_a
Status: Abstract for the paper; the constants in the port are those of Liljegren's published code. Two deliberate differences from that code:
- The direct fraction of sunlight is read from the forecast's own beam/diffuse split instead of being estimated from a clearness index.
- Wind is brought to body height with the same two-thirds factor as the rest of the engine, where the original uses a stability-class power law.
Checked against the NWS. On 11 October 2026 at 4 pm local for Oconomowoc, WI (75°F, dew point 58°F, 9 mph wind, full sun), this port gave a WBGT of 71°F. The National Weather Service's own forecast WBGT for the same grid point and hour (api.weather.gov/gridpoints/MKX/68,67, field wetBulbGlobeTemperature) was 71°F. One point is a spot check, not a validation, but it is an independent one.
6.2 Heat flag
The spec asks for the ACSM road-race flag thresholds:
| Flag | WBGT | Attune shows |
|---|---|---|
| Green | below 65°F (18°C) | nothing |
| Yellow | 65–73°F (18–23°C) | Heat risk — caution |
| Red | 73–82°F (23–28°C) | Heat risk — warning |
| Black | above 82°F (28°C) | Heat risk — danger |
Source: ACSM position stand on exertional heat illness during training and competition (Armstrong et al. 2007), carried forward from the 1996 distance-running stand. Status: Abstract for the flag bands; consistent across the secondary sources checked, with one of them rounding the yellow/red boundary to 72°F.
What the 2023 consensus changes, and what Attune does not yet do. The ACSM expert consensus statement (Roberts et al. 2023, Curr Sports Med Rep 22(4):134–149), Table 7, read from the published PDF (Primary), keeps the same structure but makes the thresholds regional. Its Category 3 (the hot Southeast and Southwest) matches the flags above: risk for all active people rises at 22.3–25.6°C, is high for the unfit and unacclimatized at 25.7–27.8°C, and continuous exercise should be cancelled at 27.9°C and above. For the middle of the country (Category 2) each band is about 1.3°C lower, and for the North (Category 1) about 3.3°C lower, because runners there are less heat-acclimatized. Attune uses the single national set the spec names. A runner in Wisconsin is therefore warned somewhat later than the 2023 table would warn them. Adopting the regional categories needs the Grundstein et al. (2015) region map; it is the first thing to add on the heat side.
Why heat matters this much. Ely et al. (2007) found marathon times slow progressively as WBGT rises from 5 to 25°C, with slower runners hit harder (top men 1.7% off the course record in the coolest quartile, 4.5% in the warmest). Status: Abstract.
6.3 Training by heart rate in the heat
Whenever the heat flag is up, the page adds one sentence for runners who train to heart rate, as in threshold work guided by lactate and heart rate: keep your usual zones and let the pace fall. It does not tell anyone to move a zone up or down, because the evidence is that the zones do not move.
| Finding | Source | Status |
|---|---|---|
| Sixteen endurance-trained cyclists and triathletes did incremental tests at 18°C and 35°C. Heart rate at blood lactate of 2, 3 and 4 mmol/L, and at both ventilatory thresholds, did not differ between the two (variation 1.4–2.9%; r = 0.92–0.95). Power output at those thresholds was 10–17% lower in the heat. The authors conclude that heart-rate thresholds found in temperate conditions can be used to prescribe training in moderate heat | Maunder et al. (2021) | Abstract |
| At a fixed work rate in 35°C, heart rate rose 12% between minutes 15 and 45 while maximal oxygen uptake fell 19%, so relative intensity rose from 63% to 78% of maximum. Heart rate was tracking the rise in how hard the body was working, which "supports the validity of using changes in HR to reflect changes in relative metabolic intensity" in the heat | Wingo et al. (2005) | Abstract |
| A review of intensity prescription in heat stress reaches the same position: the rise in heart rate in the heat comes with a matching fall in aerobic capacity | Wingo (2015) | Abstract |
| One caution. When heart rate was held constant for 45 minutes in 35°C, power had to fall 37% and relative intensity slipped from about 60% to 50% of maximum: over a long session, holding a heart rate in the heat gives a little less stimulus than the same heart rate in the cool | Wingo & Cureton (2006) | Abstract |
So the answer to "should a 160–170 sub-threshold range become 165–175 when it is hot" is no. Raising the range to hold pace means working above threshold: at the old pace in the heat, lactate and heart rate are both higher. The range stays; the pace it buys drops, by something like a tenth to a sixth at 95°F in the one study that measured it, and further as the session goes on.
Limits. The threshold study was in cyclists, in trained men, in incremental tests lasting minutes, at one level of heat. No study was found that repeats it in runners or over a full threshold session. No adjustment is offered for cold: nothing was found showing heart-rate thresholds shift there either. Attune does not compute a pace for a heart rate; it has no way to know either.
7. The cold side
7.1 Wind chill, for exposed skin only
NWS wind chill (2001), T in °F and V in mph at 10 m, defined for T ≤ 50°F and V > 3 mph:
WCT = 35.74 + 0.6215·T − 35.75·V^0.16 + 0.4275·T·V^0.16
Source: NWS Wind Chill Temperature Index brochure. Status: Primary.
Per the spec, wind chill is used only for hands, head and face and for the frostbite flag. It is never used to choose the torso or legs; those come from the body model in §8.
A runner's wind chill. The index assumes a person walking at 3 mph into the wind. A runner moves faster, so the extra airflow is converted back into the 10 m wind that would put the same air speed on a walker:
V' = V + (v_run − 1.34 m/s) / (2/3)
Status: Derived from the index's own stated assumptions (walking speed and height correction, per the brochure and Osczevski & Bluestein 2005). At an easy pace this lowers wind chill by 1–4°F.
7.2 Frostbite flag
Shown when the runner's wind chill is −18°F or lower and the air is below freezing. Source: the NWS chart's frostbite shading begins there; its own worked example is 0°F with a 15 mph wind giving −19°F and frostbite in 30 minutes. Status: Primary. The flag steps up to "danger" at −33°F, where the chart's 10-minute band begins at moderate wind speeds (Primary, read from the chart; the band boundaries on the chart depend on wind speed as well as wind chill, so this is an approximation of a curve by one number).
The freezing-air condition is from the ACSM cold-weather consensus (Castellani et al. 2021, Curr Sports Med Rep 20(11):594–607), which replaced the 2006 position stand: skin cannot freeze unless air temperature is below about −3°C. Status: Abstract.
7.3 Hands and head
There is no good source for the wind chill at which a runner should put on gloves or cover their ears. ACSM's guidance is qualitative: protect hands and head, mittens are warmer than gloves. These tiers are Tunable and were set against the spec's sanity scenarios:
| Runner wind chill | Hands | Head |
|---|---|---|
| 41°F and above | Bare | Bare (visor in sun, cap in rain) |
| 37–41°F | Thin gloves, marked optional | Bare |
| 28–37°F | Thin gloves | Ear band |
| 5–28°F | Gloves | Ear band |
| Below 5°F | Mittens | Hat |
| Below 0°F | Mittens | Hat and neck gaiter |
| −18°F and below, freezing air | Mittens | Balaclava |
Feet follow the same reading: thin socks at 41°F and above, midweight below that, thick below 20°F, and two layers below 0°F or whenever a balaclava is called for. Tunable, like the hand tiers; the two-layer advice itself is sourced in §5.1.
Why ears start at 37°F. Ears are covered from the reading at which thin gloves stop being optional, so the two pieces that come off first go on together. The line used to be 33°F. That left a 40°F morning at a 10:00 pace (a runner's wind chill of 34 to 37°F in light wind) with gloves and bare ears, which is not how runners dress for that morning. Three findings make the case for covering ears earlier. None of them gives a number:
- Ears are thin and stick out into the wind. They were the commonest site of facial frostbite in Finnish conscripts (533 of 913 cases), and going without a hat with earflaps carried an odds ratio of 18.5 (Lehmuskallio et al. 1995). That is frostbite in deep cold, not soreness at 40°F, but it says where the head loses heat first.
- A cold head drives discomfort early in exercise. In 43°F air, cyclists whose heads were fanned were less comfortable and worked harder in the first minutes than when their heads were warmed. After about five minutes a bare head was as comfortable as a warmed one (Mündel et al. 2016). So head comfort matters most at the start, which is when an ear band earns its place, and why it can be pushed up once you are warm.
- Cooling the face cuts blood flow to the fingers. Standing in a −15°C wind, people in a balaclava kept warmer fingers for the first half hour (O'Brien et al. 2011). That was deep cold and standing still, so it does not set anything here, but it points the same way.
The 37°F line keeps the 45°F anchor (§14) bare-headed. Tunable.
One adjustment, also Tunable: wet hands and ears are colder, so the reading drops 8°F when it is raining.
The wind chill here includes the wind the runner makes, so a faster runner's hands and ears are dressed for a colder reading, not a warmer one.
7.4 Cold air and the airways
Below about 5°F the air itself becomes a cost, apart from what it does to skin. Cold air is dry, and warming and wetting it on the way in cools and dries the lining of the airways, which narrows them.
| Finding | Source | Status |
|---|---|---|
| Seventeen active women ran hard at 0, −5, −10, −15 and −20°C. FEV1 fell 4–5% after every run down to −15°C and 7% at −20°C. Respiratory symptoms and overall effort rose significantly at −15°C and −20°C. The authors recommend covering the mouth | Kennedy & Faulhaber (2018), Allergy Asthma Immunol Res 10(1):43–51 | Abstract |
| Thirteen winter athletes ran hard at −20°C with and without a heat and moisture exchanger, a mask that warms and wets each breath with the one before. Without it FVC fell 5.9% and FEV1 4.2% three minutes after; with it FEV1 rose, and fewer reported symptoms | Frischhut, Kennedy, Niedermeier & Faulhaber (2020), Scand J Med Sci Sports 30(3):591–601 | Abstract |
| Twenty-three healthy trained runners did a four-minute all-out run at −15°C with and without the same kind of mask: FEV1 fell 0.5% with it against 2.7% without, a marker of damage to the airway lining rose 27% against 121%, and symptoms were milder | Stenfors et al. (2022), Eur J Appl Physiol 122(6):1473–1484 | Abstract |
| In twenty people who do get exercise-induced bronchoconstriction, peak oxygen uptake was 6.5% lower and peak running speed lower at −18°C than at 20°C | Stensrud, Berntsen & Carlsen (2007), Respir Med 101(7):1529–1536 | Abstract |
The rule. When the air temperature at any point in the run is −15°C (5°F) or below, the page asks for the mouth to be covered: a neck gaiter is added if the wind chill tiers (§7.3) had not already added one, its detail line changes from "over your nose into the wind" to "over your mouth and nose", and its reason becomes the airways. A balaclava gets the same change. The threshold is the temperature at which symptoms and effort rose in Kennedy & Faulhaber. It is read from the air temperature, not the wind chill, and the personal offset (§12) does not move it: it is about the air breathed, not how warm the runner feels.
What the studies do not show. They tested purpose-made masks, not a fabric gaiter. A gaiter over the mouth works the same way, by holding some of the warmth and water of each breath out for the next one, but how much of the effect it gives has not been measured, and the page's source note says so. None of the mask studies reports a faster run; what they show is airways that stay open and fewer symptoms. Status of applying them to a gaiter: Tunable judgment.
8. Choosing the outfit
Every candidate outfit is run through the body model for the whole run. Two numbers are read from each simulation.
8.1 The cold limit: skin temperature
A run is cold when mean skin temperature on the headwind leg falls below what is comfortable for that level of exertion. Fanger's regression (ASHRAE Handbook — Fundamentals, ch. 9), M in W/m²:
t_sk,comfortable = 35.7 − 0.0275·M
| Pace | Comfortable mean skin temperature |
|---|---|
| 10:00 | 22.6°C |
| 8:00 | 19.6°C |
| 6:30 | 16.2°C |
Status: Reference code for the equation, but used beyond the range it was fitted on (about 1–4 met; running is 8–10 met). The direction is well established — comfortable skin temperature falls as exertion rises (Gagge et al. 1969) — and ISO 11079's neutral criterion has almost the same slope (35.7 − 0.0285·M). The extrapolated values are in line with what the anchor scenarios imply: the outfits experienced runners choose produce headwind-leg skin temperatures of 20–27°C in the model.
8.2 The warm limit: skin wettedness
A run is overdressed when skin wettedness (the fraction of skin covered in sweat) on the way home exceeds 0.36. Source: Fukazawa & Havenith (2009), who found whole-body discomfort did not set in while whole-body wettedness stayed below 0.36, in men walking on a treadmill. Status: Abstract. Their later study in women found a lower limit (0.20), so this is a middle-of-the-road value that the personal offset can correct.
Gagge et al. (1969) is the reason for using two different signals: during exercise, temperature sensation tracks skin temperature and discomfort tracks sweating.
In rain the skin is wet whatever is worn, so wettedness stops meaning overdressed. The warm limit switches to the two-node model's whole-body thermal sensation staying at or below neutral.
8.3 One rule: balanced, leaning light
Balanced. Every outfit is tried out into the wind and home with it. The balanced outfit is the one that sits farthest from both limits at once: skin too cold on the way out (§8.1), sweat that cannot evaporate on the way back (§8.2). To compare a temperature margin with a wettedness margin, 3 K of skin temperature is treated as equal to 0.1 of wettedness. That exchange rate is Tunable.
So the outfit is not chosen to be warm into the wind. Warm enough into the wind is one limit, not too sweaty with it behind is the other, and the outfit has to clear both.
Leaning light. Of the outfits within 1 K of skin temperature of the balanced one, the lightest is worn. The reason is where running is fastest: across large race datasets performance peaks in cool air, about 4–10°C for the marathon and 7.5–15°C WBGT across distance events, where runners are in racing kit and a runner dressed for comfort would add a layer (§9). Between two outfits that are nearly as good, the lighter one is nearer that optimum, and a layer too many cannot always be taken off. The 1 K is Tunable; all six scenarios of §14 hold at 0.3, 0.6 and 1 K.
What is packed for a later, colder stretch of a long outing does not lean: carrying a layer costs nothing, and being cold at hour ten does.
Singlet or tee. A singlet and a tee are almost the same garment thermally (0.06 vs 0.08 clo), so the singlet is held back until the tee would already exceed the warm limit. Going without a top is not a separate outfit: to the body it is the singlet (§11.1).
Rain shells are candidates only when rain is at least 0.5 mm/h and the air is below 10°C (50°F): lower vapour resistance lets a runner go longer before strain (Holmér 2008). Both figures Tunable.
Bare legs. The body model has a single skin compartment and cannot see legs separately. So it is asked a direct question: how cold would completely uncovered skin get on the headwind leg? Shorts are allowed only while that stays within 2 K of the comfortable skin temperature. The 2 K allowance is Tunable; the reasoning is that working leg muscle keeps the skin over it warmer than a whole-body average suggests. In still, overcast air this puts the switch from shorts to tights at about 40–45°F for an easy run, which matches common practice. This uses the heat balance, not wind chill, as the spec requires.
8.4 How long the run is
A run is an hour unless the runner says otherwise, up to 12 hours. The whole outing is simulated in 15-minute segments, each with the forecast interpolated to its own time.
Pace is taken as given. The runner sets the pace they will actually run. An earlier version slowed long outings automatically; with the pace on the page that is the runner's call, and a twelve-hour day should be set at the pace it will be covered at.
Up to three hours: one outfit. It has to work start to finish, headwind for the first half and tailwind for the second, so the weather that arrives during the run is dressed for. Hands and head are dressed for the harshest segment.
Longer than three hours: what to start in, and what to pack. No single outfit suits a day that starts at 74°F in full sun and ends at 52°F after dark. The outing is split into two-hour stretches and each is dressed on its own. The page shows the outfit for the first stretch, and lists the extra pieces the warmest-dressed later stretch calls for, with the hour they are first wanted. The three-hour limit and the two-hour stretches are Tunable.
Everything that adds up or peaks — heat, frostbite, air quality, darkness, and the sun's dose (§11.1) — is judged across the whole outing, whatever its length.
9. Why it leans light
| Finding | Source | Status |
|---|---|---|
| Marathon performance slows progressively as WBGT rises from 5 to 25°C; slower runners lose more | Ely, Cheuvront, Roberts & Montain (2007), Med Sci Sports Exerc 39(3):487–493 | Abstract |
| Across 1.79 million finishers of six major marathons, speed against air temperature fits a quadratic with an optimum between 3.8 and 9.9°C depending on performance level | El Helou et al. (2012), PLOS ONE 7(5):e37407 | Abstract and main text. The per-level table is in a supplement not read |
| Across 1,258 races and 7,867 athletes, peak performance was most likely at 7.5–15°C WBGT (10–17.5°C air), and each degree of WBGT outside that band cost 0.3–0.4% | Mantzios et al. (2022), Med Sci Sports Exerc 54(1):153–161 | Abstract. The penalty is stated for departures in either direction; the abstract does not give a separate cold-side figure |
| Cooling the leg muscles cut peak sprint power 12% (muscle at 31.9°C) and 21% (29.0°C) against rest (36.6°C) | Sargeant (1987), Eur J Appl Physiol 56:693–698 | Abstract. Four subjects |
| Jump and sprint performance change about 4–5% per °C of muscle temperature | Bergh & Ekblom (1979), Acta Physiol Scand 107:33–37 | Secondary citation only |
| A running suit with 20% lower water-vapour resistance allows a longer run or a higher speed before physiological strain becomes critical | Holmér (2008), J Fiber Bioeng Inform 1(1) | Abstract |
What these support, taken together: running is fastest in air cooler than a resting person finds comfortable, with the runner lightly dressed. So when two outfits are nearly as good, the lighter is the better bet (§8.3). Vapour resistance costs speed, so shells are for cold rain only. Cold muscle loses power quickly, so legs are not left bare below the point where bare skin gets cold (§8.3).
What they do not support: none of these studies tested clothing choices directly. The penalties are for the air, in whatever the racers wore; Mantzios et al. report the cost for departures in either direction. Leaning light is a reasoned application of where the optimum sits, not a tested protocol, and its size is a judgment.
9.1 The best hour
The hour bar marks one start in the next 24 hours as Best, and the caption above it names that hour. It is the start at which the run is nearest the conditions races are run fastest in.
- The target is 50°F (10°C). El Helou et al. (2012) found marathon fields fastest at 3.8 to 9.9°C of air temperature, depending on the level of runner. Mantzios et al. (2022) found peak performances across distances from 3,000 m to the marathon likeliest at 10 to 17.5°C of air temperature. 10°C is the one temperature inside both ranges. Status: the two ranges are Abstract (both) and main text (El Helou); taking the point where they meet is a Tunable judgment.
- It is compared with feels-like, not air temperature. Feels-like is the still, shaded air temperature at which the same runner at the same pace would be as warm (§10), so wind, sun, humidity and rain all count, and so does pace.
- Both legs count. The cost of an hour is (out − 50)² + (back − 50)², with "out" the feels-like into the wind and "back" the feels-like with it behind. Squared because speed falls away from the optimum on a curve (El Helou fit a quadratic), so an hour that is right one way and hot the other is not as good as it looks on the bar, which shows the leg into the wind. Status: Derived from the shape of the fit; the studies do not give a penalty per degree of feels-like.
- A long run is weighed whole. For a run of several hours the cost is averaged over each hour of it, so the best start for three hours can be earlier than the best single hour.
- Only starts from 5 am to 9 pm are considered. Status: Tunable; the coolest hour of a summer night is no use to someone asleep.
What it does not weigh: darkness, traffic, air quality, lightning or ice. Those show as flags and extras once the hour is picked. The mark is about speed alone.
10. Feels-like
The "why" line reports a feels-like temperature. It is the still, shaded, dry day on which the same run would leave the body in the same thermal state — an equivalent temperature in the same sense as wind chill, but for a whole clothed runner and including sun, humidity and rain.
Method: simulate the first 30 minutes of the headwind leg for an index runner (a long sleeve and tights in ordinary fabric: 0.4 clo, p = 50, i_cl = 0.4) and note mean body temperature. Then find the air temperature at which the same runner in still air, in shade, at 50% humidity, reaches the same value.
Status: the construction is Derived from the body model. The index runner's clothing is a Tunable definition, in the way wind chill's bare face is a definition.
It behaves as it should. On a still, overcast, dry day it reads within 3°F of the thermometer. Compared with the NWS index in cold wind:
| Conditions | NWS wind chill | Attune feels-like |
|---|---|---|
| 25°F, 15 mph | 13°F | 10°F |
| 10°F, 18 mph | −8°F | −12°F |
| −5°F, 20 mph | −29°F | −32°F |
And where wind chill has nothing to say: 50°F in full sun and still air feels like 61°F; 72°F with a 68°F dew point in full sun feels like 82°F; 38°F in steady rain with a 10 mph wind feels like 17°F.
The feels-like number explains the outfit. It does not choose it. The outfit comes from §8.
11. Extras and the remaining flags
| Item | Rule | Source | Status |
|---|---|---|---|
| Sunglasses | Never | Not recommended, because nothing shows they make a runner faster or more efficient. The one direct test varied the light reaching the eyes with three grades of sunglasses during a 20-minute all-out ride and found no difference in power, heart rate, oxygen use or perceived exertion (O'Brien & O'Connor 2000). They protect eyes and are worth wearing for that; Attune only lists what changes the run | Abstract |
| Visor or cap | Same sunshine test, when it is too warm for a hat. A brimmed cap in rain | — | Tunable |
| Sunscreen, or covering up | By the peak UV index and the time spent at 3 or above: see §11.1 | WHO, ARPANSA, Cancer Council | §11.1 |
| Reflective bands | Sun below the horizon at any point in the run: civil twilight or darker | Drivers lose sight of a runner well before the runner loses sight of the road. Across eleven years of US fatal crashes, compared at the same clock hour either side of the daylight-saving changes, pedestrians were up to seven times more at risk in the dark (Sullivan & Flannagan 2002). Reflective material on the moving joints, ankles and wrists, is recognised as a person at much longer distances than the same material on the torso (Wood 2023, reviewing closed-road trials) | Abstract |
| A light | Sun more than 6° below the horizon at any point: nautical twilight or darker | The definition of civil twilight is that there is still light enough to see the ground and carry on outdoors without artificial light; past it there is not (US Naval Observatory definitions, as published by the National Weather Service) | Reference |
| Traction | Snow on the ground (1 cm or more), snow falling (over 0.1 cm/h), or precipitation at or below 33°F | — | Tunable |
| Poor air quality | AQI ≥ 101 caution, ≥ 151 warning, ≥ 201 danger | EPA Air Quality Guide for Particle Pollution: at 101–150 sensitive groups should reduce prolonged or heavy exertion; at 151–200 everyone should | Abstract |
| Conditions shifting | Feels-like spans 10°F or more between its coldest and warmest hour of the run, or rain begins during it | — | Tunable |
| NWS alert | Passed through from api.weather.gov for the point, when it is in force at some time during the run | NWS | Primary |
What the why line mentions is a wording choice, not a recommendation, and its thresholds are Tunable: wind is named from 8 mph, humidity when air and dew point are both 60°F or more, sun as "full" when the absorbed solar load is 90 W/m² or more, and rain as "steady" from 1 mm/h.
Air quality blending (server/airquality.ts) follows Freshen: monitors within 25 miles (the radius AirNow's own retired point service used), the nearest three per pollutant weighted by inverse distance, the worst pollutant reported. The monitor reading anchors the current hour and its gap to the modeled forecast fades to zero over 12 hours; with no model, a reading is trusted for 6 hours. The three, the 12 and the 6 are Tunable. Without an AirNow key the flag uses the modeled AQI alone.
11.1 Sun on skin
Dressing for temperature alone can put a runner in a singlet under a sun that burns them, and a burn is not only a skin problem. Pandolf et al. (1992) sunburned ten men and put them in 22°C water: the burn impaired their ability to constrict skin blood vessels, so they lost more heat, and the effect was still there a week later, after the redness had gone. A companion study in the heat found local sweating reduced at burned sites. A long day that ends after dark is exactly where that costs: burned by afternoon, colder than expected by night. Status: Abstract (both papers).
The data. Open-Meteo's hourly UV index, already in the forecast request. It accounts for cloud and ozone. Its developer notes the forecast endpoint's value is derived from the GFS model and runs slightly higher than the CAMS-based one, which errs toward caution. Checked against the official forecast: on 11 October 2026 for ZIP 53066, the EPA/NWS hourly UV forecast read 1, 2, 3, 4, 4, 4, 3 from 9 am to 3 pm; Open-Meteo read 1.0, 2.1, 3.2, 4.1, 4.4, 4.3, 3.6. One day is a spot check, not a validation.
The rule is a dose, the same for everyone. No skin type is assumed or asked for. Attune recommends sun protection only when the run would otherwise add up to a burn that costs the runner something, because that is the only kind of recommendation it makes. Sunscreen is worth wearing for your skin's sake well below this; that is a health decision, and it is yours.
- The dose. The UV index is defined so that an hour at UV index 1 delivers 0.9 standard erythemal doses (SED; 1 SED = 100 J/m² of erythemally weighted UV, and one UV index unit is 25 mW/m²). Status: Reference (WHO 2002; CIE).
- The burn that costs something. Pandolf's subjects were given twice their minimal erythemal dose. Fair skin that burns easily first reddens at about 2.5 SED, so the yardstick is 5 SED. Using fair skin for everyone errs toward protecting. Status: Abstract for the burn; Reference for the 2.5 SED; the choice of fair skin is Tunable.
- What counts. Only hours with the UV index at 3 or above. Below 3 the agencies say no protection is needed however long you are out (WHO; ARPANSA; Cancer Council), and the evidence that very long, very weak exposures add up the same way is thin. Status: Abstract; the cutoff is Tunable.
| Sun over the run | Recommendation | Status |
|---|---|---|
| Under 5 SED from hours at UV 3 or above | Nothing | Derived from the above |
| 5 SED or more, with no more than two hours at UV 3 or above | Sunscreen | Derived |
| 5 SED or more, more than two hours, heat flag off | Cover up: a sun shirt or sleeves and a cap, with sunscreen on what is left showing | See the trade below |
| 5 SED or more, two to four hours, heat flag on | Sunscreen, with a fresh coat every two hours, and a cap | See the trade below |
| 5 SED or more, more than four hours | Cover up, whatever the heat | Sunscreen has failed in exactly these events; see below. Tunable |
Cover or sunscreen is a trade. The same patch of skin can be protected two ways, and they cost differently. Term by term, for arms and shoulders in the sun:
| What changes | Sleeves (thin, pale) | Sunscreen |
|---|---|---|
| Sunlight absorbed | Less: pale fabric reflects part of what skin would absorb, though thin fabric also lets some through | No change: sunscreen works on UV, about 5% of the sun's energy |
| Heat lost to the air (air cooler than skin, below about 93°F) | Slightly less: one more thin layer | No change |
| Heat gained from the air (air hotter than skin) | Slightly less, which helps | No change |
| Sweat evaporating | Slightly harder: vapour has a layer to cross, and in humid air that layer is the bottleneck | No change for most products; some, mineral ones especially, reduce sweating where they sit (Aburto-Corona & Aragón-Vargas 2016), others do not (Connolly & Wilcox 2000) |
| UV reaching skin | Blocked, for as long as the sleeve is on (Berry et al. 2022) | Reduced, by less than the label says at the thickness people apply, and less again as it sweats off (Faurschou & Wulf 2007) |
So sleeves protect better and cost a little evaporation; sunscreen costs nothing thermally and protects worse for less time. Which wins turns on whether evaporation is what the runner is short of.
- The measurements. Under hot lamps and a fan at a WBGT of 84°F, a long-sleeved shirt over the torso and arms cost nothing against bare skin at an easy effort, and raised body temperature, heart rate and sweat loss at a moderate one (Tsuji et al. 2014). Out of the sun in dry heat, a fitted shirt and no shirt stored the same heat (D'Souza et al. 2019). So the cost of cover is real, small, and shows up only when the runner is working hard in heat. Status: Abstract.
- The body model cannot settle it. It was tried: the run was simulated with 0.06 clo of sleeves added (the gap between ASHRAE 55's short- and long-sleeved shirts) across 50–100°F, dry and humid, easy and race. The differences came out at a few tenths of a degree of core temperature over three hours, with the sign changing between neighbouring cases. That is below what a one-compartment skin model can resolve, so the rule does not lean on it.
- The rule, then, uses the one clean signal there is: the heat flag. Below a WBGT of 65°F (ACSM's yellow flag, §6.2) heat is not limiting, the runner has evaporation to spare, and sleeves cost nothing: cover. At or above it, evaporation is the one way heat leaves and the measured cost of cover begins: sunscreen, reapplied. Status: Derived from the above; the choice of the yellow flag as the line is Tunable.
- Two hours is the interval agencies give for reapplying, a convention with little documented basis for the exact figure. One reapplication is taken as the most a runner can be counted on to do; past four hours the answer is cover regardless, because that is where sunscreen has been seen to fail (the Ironman and ultra doses above). Both Tunable.
- A top that already has sleeves needs no sun shirt, only sunscreen on what shows.
- A cap goes on in every case past plain sunscreen: an hour's running at 31°C with and without one found no difference in body temperature, sweat loss or heart rate (Wimer 2009), so its shade is free.
Two cases, worked:
| Cool, UV index 10, three hours | 100°F, UV index 10, three hours | |
|---|---|---|
| Heat flag | Off | On, at its highest level |
| Says | Sleeves and a cap, sunscreen on the rest | Sunscreen with a fresh coat every two hours, and a cap. And: pick another hour |
| Why | Nothing to lose by covering, and fabric blocks what sunscreen only reduces | Sweat is the only way heat is leaving; nothing goes over it that does not have to |
What that comes to:
| Run | Dose | Says |
|---|---|---|
| 1 hour at UV 3 | 2.7 SED | Nothing |
| 1 hour at UV 5 | 4.5 SED | Nothing |
| 1 hour at UV 6 | 5.4 SED | Sunscreen |
| 1 hour at UV 10 | 9 SED | Sunscreen |
| 2 hours at UV 3 | 5.4 SED | Sunscreen |
| 3 hours at UV 4, 48°F | 10.8 SED | Cover up |
| 3 hours at UV 6, 84°F | 16.2 SED | Sunscreen, reapplied |
| A summer day out | 30 SED and up | Cover up |
A flag appears only when covering up is called for. The page always shows the peak UV index beside air temperature and wind.
What changed and why. An earlier version said sunscreen from UV index 3 and cover from 8, whatever the length of the run. Those are the public-health thresholds, set to limit lifetime skin damage. An hour at UV 3 delivers about one minimal dose for the fairest skin: it protects your skin to cover it, but nothing shows it changes the run.
Cover or sunscreen? Cover first, sunscreen for the gaps. Three lines of evidence:
- Protection. Sun-safety agencies list clothing first and say sunscreen should never be the only protection (Cancer Council Australia; ARPANSA; WA Health). A 2022 laboratory comparison found modern fabrics out-protected two broad-spectrum sunscreens on every measure and called clothing "the cornerstone" (Berry et al. 2022). Status: Abstract; the study was small and laboratory-based.
- Sunscreen is applied thin and wears off. SPF is measured at 2 mg/cm²; a European survey found a median of 0.39 mg/cm² actually applied, and protection falls steeply with thickness (Faurschou & Wulf 2007, magnitude disputed by a manufacturer). An Ironman case study reported visible burn at the finish despite water-resistant SPF 25. Field dosimeters put runners in a 154 km mountain ultra at about 24 standard erythemal doses and Ironman competitors above 30, several times what reddens fair skin. Status: Abstract.
- Efficiency. Some sunscreens reduce local sweating: a mineral sunscreen cut it as much as an antiperspirant in one trial (Aburto-Corona & Aragón-Vargas 2016), and a 2024 follow-up found reductions with several products, while an older study found no effect on heat loss (Connolly & Wilcox 2000). The evidence is mixed, but fabric over the skin does not carry that risk and never needs reapplying. Covering the arms costs little heat: running trials find no core-temperature difference between shirt fabrics (Sperlich et al. 2013), and under strong artificial sun at 32°C, long sleeves produced a smaller rise in body temperature than short ones in resting subjects. No trial was found that tests sun sleeves on runners directly, so the size of the cost is not established; the direction of the evidence is that it is small.
Going without a top. Out of the sun, a fitted shirt and bare skin stored the same heat (D'Souza et al. 2019), so the model does not choose between them: it picks the singlet, and whenever the UV index stays under 3 for the whole run the page adds "or tarps off" under it, runners' slang for shirt off. It is the runner's call, at any temperature at which a singlet is the answer. Under a UV index of 3 or more the line is not shown and the singlet stays on, as sun protection. Whether bare skin runs cooler in full sun is not settled: one trial at 22°C found no difference between running shirtless and in a shirt, and a study under radiant heat found a mesh shirt reduced heat storage. Status: Abstract. An earlier version offered it only under a heat flag; nothing in the studies supports that line, so it was removed.
The twilights. The sun's height is worked out for the runner's own place and minute (src/engine/sun.ts), so these follow the real length of dusk at that latitude and season, not a fixed time after sunset. Civil twilight is the sun 0° to 6° below the horizon, nautical 6° to 12°, astronomical 12° to 18°. Nautical and astronomical are treated alike: both are too dark to run by. Cloud, moonlight and street lighting are not modeled.
Not modeled: altitude (WHO: roughly 10% more UV per 1,000 m); reflection from snow, sand or water; shade; the UPF of particular fabrics; and the burn itself is not fed back into the body model for later hours — the page warns instead.
12. The personal offset
One number, in °F, stored on the device. It shifts the air and radiant temperature the body model sees, and the wind chill used for hands and head.
- Too cold moves it 2°F colder. Too warm moves it 2°F warmer. Just right leaves it alone.
- It is bounded at ±12°F.
The step and the bound are Tunable. The reasoning: 2°F is smaller than the gap between adjacent outfits (roughly 5–10°F), so one tap never causes a jump, and three or four consistent taps move a runner one full step. ±12°F spans the population differences the offset is meant to absorb. A 55 kg runner and a 95 kg runner at the same pace differ by about 15% in heat production per m² of skin, and the two sexes differ in the wettedness comfort limit (§8.2); in the model each of those is worth several °F.
The offset deliberately does not move the heat flag or the frostbite flag. Those are safety thresholds, not preferences.
13. Every tunable in one place
| # | Constant | Value | Where |
|---|---|---|---|
| 1 | Default pace; how much slower a warm-up is | 10:00 a mile; 30% | pace.ts, App.tsx |
| 2 | Singlet insulation | 0.06 clo | clothing.ts |
| 3 | Garment air permeability and shell vapour efficiency | see §5 | clothing.ts |
| 4 | Top/bottom area split | 55 / 45 | clothing.ts |
| 5 | Ground and snow albedo | 0.2 / 0.8 | environment.ts |
| 6 | Rain: wet threshold, soaking rate, rain-held wettedness, rain blocking (vest / wind shell / rain shell), dry-snow factor | 0.2 mm/h, 1 mm/h, 0.3, 0.2 / 0.6 / 0.9, 0.2 | recommend.ts, environment.ts, clothing.ts |
| 7 | Comfort exchange rate | 3 K ↔ 0.1 wettedness | recommend.ts |
| 8 | Bare-leg allowance | 2 K | recommend.ts |
| 9 | How far the outfit leans light | 1 K of skin temperature | recommend.ts |
| 10 | Rain-shell conditions | ≥ 0.5 mm/h and < 10°C | recommend.ts |
| 11 | Hands and head tiers, wet penalty | see §7.3 | recommend.ts |
| 13 | Run length: one-outfit limit; length of each stretch beyond it; shifting-conditions threshold | 3 h; 2 h; 10°F | recommend.ts |
| 14 | Personal offset step and bound | 2°F; ±12°F | feedback.ts |
| 15 | Snow cover, snowfall and snow-glare thresholds | 1 cm; 0.1 cm/h; sun 5° up | hours.ts, recommend.ts |
| 16 | Why-line wording thresholds | 8 mph; 60°F; 90 W/m²; 1 mm/h | recommend.ts |
| 17 | Air quality blending | 3 sites; 12 h fade; 6 h persistence | server/airquality.ts |
| 18 | Feels-like index runner | 0.4 clo, p = 50, i_cl = 0.4, 30 min | recommend.ts |
| 19 | Sun: the dose worth protecting against, and whose skin sets it; the UV index below which sun is not counted; how long one coat of sunscreen is counted on before covering up instead; the no-top rule | 5 SED, fair skin; 3; 2 h; heat flag and UV under 3 | recommend.ts |
| 20 | Sock tiers | 41 / 20 / 0°F | recommend.ts |
| 21 | The wording of each piece's detail line | see §5.1 | copy.ts |
| 22 | Best hour: the target it is measured from; the hours a run might start | 50°F; 5 am to 9 pm | schedule.ts |
14. The sanity scenarios
Default runner, no offset. The spec calls these judgment anchors, not exact targets, and asks that disagreements be flagged rather than forced.
| Conditions | Pace | Anchor | Engine | Match |
|---|---|---|---|---|
| 45°F, overcast, light wind, dry | 10:00 | Long sleeve or tee, shorts; light gloves optional | Tee, shorts, thin gloves | Yes |
| 25°F, 15 mph, cloudy | 10:00 | Long-sleeve base and wind jacket, tights, gloves, ear cover | Long sleeve + wind jacket, tights, gloves, ear band | Yes |
| 25°F, 15 mph, cloudy | 7:00 | Lighter than at 10:00 | Long sleeve, tights, gloves, ear band | Yes |
| 72°F, dew point 68°F, full sun | 10:00 | Singlet, shorts, cap or visor; heat flag | Singlet, shorts, visor, sunscreen; heat warning (WBGT 79°F) | Yes |
| 38°F, steady rain, 10 mph | 10:00 | Long sleeve and light shell, tights or shorts, gloves, cap | Long sleeve + wind jacket, tights, gloves, cap | Yes |
| 10°F, wind chill −8°F, before sunrise | 10:00 | 2–3 top layers, tights, mittens, hat, neck gaiter, light or reflective gear | Base + midlayer + wind jacket, tights, mittens, hat, neck gaiter, reflective bands, a light | Yes |
The third row was "Workout" when there were effort buttons; it is now the same weather at a faster pace.
All six land. That is partly by construction: the tunables in §13 marked as set against the anchors (the hands and head tiers, the rain wettedness, the comfort exchange rate, the bare-leg allowance and the lean toward light) were chosen with these scenarios in view. What was not fitted is the physics underneath — heat production, the two-node body, the ISO 11079 wind terms, the solar load, the comfort limits from Fanger and Fukazawa & Havenith — and it is the physics that makes workout come out lighter than easy, and wind matter more than temperature.
Where the science and the anchors pull apart, mildly:
- Sun. At 50°F in full sun with a light wind, the engine chooses a singlet at 10:00 a mile, where most runners would say tee. Full sun at midday is a large heat load in the model (about +11°F of feels-like in still air). The model may be right and convention cautious, or the open-sky assumption may overstate the sun on a typical route. Flagged, not forced.
- Wind jackets versus midlayers. In moderate cold the model sometimes prefers a wind jacket over a single layer where a second knit layer would be the conventional choice, and the two are close to equivalent in the simulation. Which one is shown can flip between adjacent hours. Both are reasonable; neither was forced.
- Fast paces in mild cold. At 6:00 to 8:00 a mile the engine recommends a tee or singlet and shorts down to about 35–40°F in light wind, with gloves. That is what the heat balance says and close to what competitive racers wear; for a relaxed run at those paces many would add a layer. The "too cold" button moves it.
15. Known limits
- One skin compartment. No separate arms, legs or torso. Arm sleeves, shorts-versus-tights and vest-versus-jacket are handled by rules around the model (§8.4), not inside it.
- Extrapolation. The comfort skin temperature (§8.1), the wind correction's gait term and insulation range (§4.3), and the two-node model itself are all used at higher exertion than they were validated at.
- National heat thresholds, not the 2023 regional ones (§6.2).
- Open terrain and open sky. Sheltered or shaded routes are milder than modeled.
- Long days are planned as running. A 12-hour outing is modeled at a faded running pace throughout; stops, walking and aid stations are not.
- Steady pace. The run is modeled at one pace throughout, not as intervals with recoveries. The warm-up line (§2) is a second run of the model, 30% slower, not a simulation of the session.
- Rain (§4.5) rests on the fewest measurements.
- No acclimatization. The same runner is modeled in April and August. The personal offset can follow a runner through a season only as fast as they give feedback.
- Sources read at abstract level are marked. Nothing here is claimed from a paper's full text unless the status says Primary.
16. References
Standards and position statements
- ACSM. Guidelines for Exercise Testing and Prescription — metabolic equations for running.
- Armstrong LE, Casa DJ, Millard-Stafford M, et al. (2007). Exertional heat illness during training and competition. ACSM position stand. Med Sci Sports Exerc 39(3):556–572.
- Roberts WO, Armstrong LE, Sawka MN, Yeargin SW, Heled Y, O'Connor FG (2023). ACSM expert consensus statement on exertional heat illness: recognition, management, and return to activity. Curr Sports Med Rep 22(4):134–149. doi:10.1249/JSR.0000000000001058
- Kennedy MD, Faulhaber M (2018). Respiratory function and symptoms post cold air exercise in female high and low ventilation sport athletes. Allergy Asthma Immunol Res 10(1):43–51. doi:10.4168/aair.2018.10.1.43
- Frischhut C, Kennedy MD, Niedermeier M, Faulhaber M (2020). Effects of a heat and moisture exchanger on respiratory function and symptoms post-cold air exercise. Scand J Med Sci Sports 30(3):591–601. doi:10.1111/sms.13603
- Stenfors N, Persson H, Tutt A, et al. (2022). A breathing mask attenuates acute airway responses to exercise in sub-zero environment in healthy subjects. Eur J Appl Physiol 122(6):1473–1484. doi:10.1007/s00421-022-04939-x
- Stensrud T, Berntsen S, Carlsen KH (2007). Exercise capacity and exercise-induced bronchoconstriction (EIB) in a cold environment. Respir Med 101(7):1529–1536. doi:10.1016/j.rmed.2006.12.011
- Castellani JW, Young AJ, Ducharme MB, et al. (2006). Prevention of cold injuries during exercise. ACSM position stand. Med Sci Sports Exerc 38(11):2012–2029.
- Castellani JW, Eglin CM, Ikäheimo TM, Montgomery H, Paal P, Tipton MJ (2021). ACSM expert consensus statement: injury prevention and exercise performance during cold-weather exercise. Curr Sports Med Rep 20(11):594–607. doi:10.1249/JSR.0000000000000907
- Mündel T, Raman A, Schlader ZJ (2016). Head temperature modulates thermal behavior in the cold in humans. Temperature 3(2):298–306. doi:10.1080/23328940.2016.1156214
- Lehmuskallio E, Lindholm H, Koskenvuo K, Sarna S, Friberg O, Viljanen A (1995). Frostbite of the face and ears: epidemiological study of risk factors in Finnish conscripts. BMJ 311(7021):1661–1663. doi:10.1136/bmj.311.7021.1661
- O'Brien C, Castellani JW, Sawka MN (2011). Thermal face protection delays finger cooling and improves thermal comfort during cold air exposure. Eur J Appl Physiol 111(12):3097–3105. doi:10.1007/s00421-011-1931-2
- ASHRAE Standard 55, Thermal Environmental Conditions for Human Occupancy — garment insulation table; SolarCal.
- ASHRAE Handbook — Fundamentals, ch. 9, Thermal Comfort — two-node model; Fanger's comfort regressions.
- ISO 11079:2007, Determination and interpretation of cold stress when using required clothing insulation (IREQ) and local cooling effects.
- ISO 9920:2007, Estimation of thermal insulation and water vapour resistance of a clothing ensemble.
- ISO 8996, Determination of metabolic rate.
- National Weather Service. Wind Chill Temperature Index (brochure and chart, effective 1 Nov 2001). https://www.weather.gov/media/owlie/wind-chill-brochure.pdf
- National Weather Service. Wet Bulb Globe Temperature. https://www.weather.gov/tsa/wbgt
- National Weather Service. Definitions of twilight (civil, nautical, astronomical). https://www.weather.gov/fsd/twilight
- US EPA. Air Quality Guide for Particle Pollution; UV Index Scale.
- US EPA / National Weather Service. Hourly UV Index forecast (Envirofacts
getEnvirofactsUVHOURLY). - WHO, WMO, UNEP, ICNIRP (2002). Global Solar UV Index: A Practical Guide.
- Cancer Council Australia; ARPANSA; WA Department of Health. SunSmart guidance: sun protection from UV index 3, clothing first.
- WMO. Guide to Instruments and Methods of Observation — sunshine duration threshold of 120 W/m².
Papers
- Aburto-Corona J, Aragón-Vargas LF (2016). Sunscreen use and sweat production in men and women. J Athl Train 51(9).
- Arens E, Hoyt T, Zhou X, Huang L, Zhang H, Schiavon S (2015). Modeling the comfort effects of short-wave solar radiation indoors. Building and Environment 88:3–9.
- Brimicombe C, Lo CHB, Pappenberger F, et al. (2023). Wet bulb globe temperature: indicating extreme heat risk on a global grid. GeoHealth 7(2):e2022GH000701.
- Berry EG, et al. (2022). Slip versus Slop: a head-to-head comparison of UV-protective clothing to sunscreen. Cancers 14(3).
- Bergh U, Ekblom B (1979). Influence of muscle temperature on maximal muscle strength and power output in human skeletal muscles. Acta Physiol Scand 107(1):33–37.
- Bröde P, Havenith G, Wang X, et al. (2008). Non-evaporative effects of a wet mid layer on heat transfer through protective clothing. Eur J Appl Physiol 104:341–349.
- Connolly DAJ, Wilcox AR (2000). The effects of an application of suncream on selected physiological variables during exercise in the heat. J Sports Med Phys Fitness 40(1).
- D'Souza AW, Notley SR, Brown EK, Poirier MP, Kenny GP (2019). The Hexoskin physiological monitoring shirt does not impair whole-body heat loss during exercise in hot-dry conditions. Appl Physiol Nutr Metab 44(3):332–335. doi:10.1139/apnm-2018-0370
- El Helou N, Tafflet M, Berthelot G, et al. (2012). Impact of environmental parameters on marathon running performance. PLOS ONE 7(5):e37407. doi:10.1371/journal.pone.0037407
- Ely MR, Cheuvront SN, Roberts WO, Montain SJ (2007). Impact of weather on marathon-running performance. Med Sci Sports Exerc 39(3):487–493.
- Faurschou A, Wulf HC (2007). The relation between sun protection factor and amount of sunscreen applied in vivo. Br J Dermatol 156(4):716–719.
- Fukazawa T, Havenith G (2009). Differences in comfort perception in relation to local and whole body skin wettedness. Eur J Appl Physiol 106(1):15–24.
- Gagge AP, Stolwijk JAJ, Saltin B (1969). Comfort and thermal sensations and associated physiological responses during exercise at various ambient temperatures. Environ Res 2:209–229.
- Gagge AP, Fobelets AP, Berglund LG (1986). A standard predictive index of human response to the thermal environment. ASHRAE Trans 92(2B):709–731.
- Gavin TP (2003). Clothing and thermoregulation during exercise. Sports Med 33(13):941–947. doi:10.2165/00007256-200333130-00001
- Grundstein A, Williams C, Phan M, Cooper E (2015). Regional heat safety thresholds for athletics in the contiguous United States. Applied Geography 56:55–60.
- Havenith G, Holmér I, den Hartog EA, Parsons KC (1999). Clothing evaporative heat resistance — proposal for improved representation in standards and models. Ann Occup Hyg 43(5):339–346.
- Havenith G, Nilsson HO (2004). Correction of clothing insulation for movement and wind effects, a meta-analysis. Eur J Appl Physiol 92:636–640 (and erratum).
- Holmér I (1985). Heat exchange and thermal insulation compared in woolen and nylon garments during wear trials. Textile Research Journal 55(9):511–518.
- Holmér I (2008). How is performance in the heat affected by clothing? J Fiber Bioeng Inform 1(1):7–12.
- Garzón-Mosquera JC, Aragón-Vargas LF (2024). The impact of some sunscreens on local sweating differs in men and women during exercise in the heat.
- Glove and mitten protection in extreme cold weather: an Antarctic study (2016). Int J Circumpolar Health.
- Jay O, Bain AR, Deren TM, Sacheli M, Cramer MN (2011). Large differences in peak oxygen uptake do not independently alter changes in core temperature and sweating during exercise. Am J Physiol Regul Integr Comp Physiol 301(3):R832–R841. doi:10.1152/ajpregu.00257.2011
- Knapik JJ, Hamlet MP, Thompson KJ, Jones BH (1996). Influence of boot-sock systems on frequency and severity of foot blisters. Mil Med 161(10):594–598.
- Liljegren JC, Carhart RA, Lawday P, Tschopp S, Sharp R (2008). Modeling the wet bulb globe temperature using standard meteorological measurements. J Occup Environ Hyg 5(10):645–655.
- Mantzios K, Ioannou LG, Panagiotaki Z, et al. (2022). Effects of weather parameters on endurance running performance: discipline-specific analysis of 1258 races. Med Sci Sports Exerc 54(1):153–161.
- Measured UV exposures of Ironman, Sprint and Olympic-distance triathlon competitors (2020). Atmosphere 11(5):440. doi:10.3390/atmos11050440
- Osczevski R, Bluestein M (2005). The new wind chill equivalent temperature chart. Bull Am Meteorol Soc 86(10):1453–1458.
- Pandolf KB, et al. (1992). Human thermoregulatory responses during heat exposure after artificially induced sunburn. Am J Physiol 262(4):R610–R616.
- Pandolf KB, et al. (1992). Human thermoregulatory responses during cold water immersion after artificially induced sunburn. Am J Physiol 262(4):R617 onward.
- Riegel PS (1981). Athletic records and human endurance. American Scientist 69(3):285–290.
- Sargeant AJ (1987). Effect of muscle temperature on leg extension force and short-term power output in humans. Eur J Appl Physiol 56(6):693–698.
- Serrano et al. (2011). Ultraviolet exposure for different outdoor sports in Valencia, Spain. Photodermatol Photoimmunol Photomed.
- Solar ultraviolet radiation exposure of trail runners in an ultraendurance competition at high altitude (2025). J Photochem Photobiol A 460:116139.
- Sperlich B, Born DP, Lefter MD, Holmberg HC (2013). Exercising in a hot environment: which T-shirt to wear? Wilderness Environ Med 24(3).
- Di Domenico I, Hoffmann SM, Collins PK (2022). The role of sports clothing in thermoregulation, comfort, and performance during exercise in the heat: a narrative review. Sports Med Open 8(1):58. doi:10.1186/s40798-022-00449-4
- Sullivan JM, Flannagan MJ (2002). The role of ambient light level in fatal crashes: inferences from daylight saving time transitions. Accid Anal Prev 34(4):487–498. doi:10.1016/s0001-4575(01)00046-x
- Wood JM (2023). Improving the conspicuity and safety of pedestrians and cyclists on night-time roads. Clin Exp Optom 106(3):227–237. doi:10.1080/08164622.2023.2174001
- Maunder E, Plews DJ, Merien F, Kilding AE (2021). Stability of heart rate at physiological thresholds between temperate and heat stress environments in endurance-trained males. Int J Sports Physiol Perform 16(8):1204–1207. doi:10.1123/ijspp.2020-0351
- Wimer GS (2009).
- Wingo JE, Lafrenz AJ, Ganio MS, Edwards GL, Cureton KJ (2005). Cardiovascular drift is related to reduced maximal oxygen uptake during heat stress. Med Sci Sports Exerc 37(2):248–255. doi:10.1249/01.mss.0000152731.33450.95
- Wingo JE, Cureton KJ (2006). Maximal oxygen uptake after attenuation of cardiovascular drift during heat stress. Aviat Space Environ Med 77(7):687–694.
- Wingo JE (2015). Exercise intensity prescription during heat stress: a brief review. Scand J Med Sci Sports 25 Suppl 1:90–95. doi:10.1111/sms.12381 Wearing a cap, thermoregulation, and thermal sensation during running in a hot environment. J Sports Med Phys Fitness 49(3):272–277.
- Nielsen B (1990). Solar heat load: heat balance during exercise in clothed subjects. Eur J Appl Physiol 60(6):452–456. doi:10.1007/BF00705036
- O'Brien PM, O'Connor PJ (2000). Effect of bright light on cycling performance. Med Sci Sports Exerc 32(2):439–447. doi:10.1097/00005768-200002000-00027
- Tsuji M, Kume M, Tuneoka H, Yoshida T (2014). Differences in the heat stress associated with white sportswear and being semi-nude in exercising humans under conditions of radiant heat and wind at a wet bulb globe temperature of greater than 28 °C. Int J Biometeorol 58(6):1393–1402. doi:10.1007/s00484-013-0722-3
- Thompson RL, Hayward JS (1996). Wet-cold exposure and hypothermia: thermal and metabolic responses to prolonged exercise in rain. J Appl Physiol 81(3):1128–1137.
- Comparison of correction factor for both dynamic total thermal insulation and evaporative resistance between ISO 7933 and ISO 9920 (2020). J Physiol Anthropol. doi:10.1186/s40101-020-00235-9
- Weller AS, Millard CE, Stroud MA, Greenhaff PL, Macdonald IA (1997). Physiological responses to a cold, wet, and windy environment during prolonged intermittent walking. Am J Physiol 272:R226–R233.
Reference implementation
- Tartarini F, Schiavon S (2020). pythermalcomfort: a Python package for thermal comfort research. SoftwareX 12:100578. Version 4.6.1 used for the two-node parity test and for the ISO 11079, SolarCal and ASHRAE 55 garment values.
Data on typical paces
- Strava, Year in Sport 2018 (average run pace 9:48 per mile).